Author: Karner, V.L.
Paper Title Page
TUIXA04 First Results from beta-SRF- Testing SRF Samples at High Parallel Field 374
 
  • E. Thoeng, R. Kiefl, W.A. MacFarlane, J.O. Ticknor
    UBC & TRIUMF, Vancouver, British Columbia, Canada
  • M. Asaduzzaman, S.R. Dunsiger, D. Fujimoto, T. Junginger, V.L. Karner, P. Kolb, R.E. Laxdal, R. Li, R.M.L. McFadden, G. Morris, M. Stachura
    TRIUMF, Vancouver, Canada
  • T. Junginger, R.M.L. McFadden
    UVIC, Victoria, Canada
 
  The new ¿-SRF facility at TRIUMF has recently been commissioned. A new 1 m extension has been added to an existing ¿-NMR beamline with a large Helmholtz coil to produce fields up to 200 mT parallel to sample surfaces. The ¿-NMR technique allows depth dependent characterization of the local magnetic field in the first 100 nm of the sample surface making the probe ideal for studying Meissner screen- ing in heat treated Niobium or layered SRF materials. First measurements of Meissner screening at fields up to 200 mT have been analyzed. The results show clear differences in the Meissner screening of baseline treatments compared to mid-T baked (O-doped) Niobium.  
slides icon Slides TUIXA04 [1.644 MB]  
DOI • reference for this paper ※ doi:10.18429/JACoW-SRF2023-TUIXA04  
About • Received ※ 24 June 2023 — Revised ※ 28 June 2023 — Accepted ※ 06 July 2023 — Issue date ※ 09 July 2023
Cite • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)