  Tem­per­a­ture map­ping (T-map) on su­per­con­duct­ing ra­dio-fre­quency (SRF) cav­i­ties has been shown as a use­ful tool to iden­tify de­fects and other ab­nor­mal sources of losses. So far T-map sys­tems have only been re­al­ized for el­lip­ti­cal cav­i­ties that have an eas­ily ac­ces­si­ble outer sur­face. TEM mode cav­i­ties such as quar­ter­wave and halfwave res­onators (QWR, HWR) dis­si­pate most of their power on the inner con­duc­tor of the coax­ial struc­ture. The lim­ited ac­cess and con­strained space are a chal­lenge for the de­sign of a tem­per­a­ture map­ping sys­tem. This paper de­scribes the me­chan­i­cal and elec­tri­cal de­sign in­clud­ing the data ac­qui­si­tion of a T-map sys­tem for the TRI­UMF multi-mode coax­ial cav­i­ties, and first re­sults are shown.  