Author: Quinlan, M.B.
Paper Title Page
WEPWB076 Low Particulates Nitrogen Purge and Backfill during Prototype HB650 Cryomodule String Assembly 765
 
  • T.J. Ring, M.B. Quinlan, G. Wu
    Fermilab, Batavia, Illinois, USA
 
  Funding: This manuscript has been authored by Fermi Research Alliance, LLC, under Contract No. DE-AC02-07CH11359 with the U.S. Department of Energy, Office of Science, Office of High Energy Physics.
A low particulate vacuum and purging system was developed to support PIP-II cryomodule string assembly. The overpressure can be controlled at a precision of 1 mbar above the atmospheric pressure regardless of the cavity or string assembly air volume. The system minimized the risk of uncontrolled nitrogen flow during the string assembly. Design features will be presented.
 
DOI • reference for this paper ※ doi:10.18429/JACoW-SRF2023-WEPWB076  
About • Received ※ 19 June 2023 — Revised ※ 24 June 2023 — Accepted ※ 26 June 2023 — Issue date ※ 09 July 2023